page 3
d. Quick Reference Tables
Command Reference: Each of the following commands (CMD) begins a code sequence to perform a
specific function.
CMD Function
2 2 * Change six-digit user code.
2 8 * Download the event audit trail.
3 2 * Set up the Management/Employee enabling/disabling of user codes.
3 8 * Enable/disable the duress function
4 3 * Identify the type of lock.
4 6 * Program the time delay override option.
5 5 * Enable/disable user codes (with Master or Supervisor Code, in Management/Employee mode).
5 6 * Set up user code disabling.
6 7 * Define and use the Management Reset Code.
7 4 *
Program functions (require Master Code)
- Define or change the time delay period (1-99 minutes)
- Define or change the opening window (1-10 minutes)
- Add/delete Supervisor Code
Program functions (require Master or Supervisor Code)
- Add user codes 2-8
- Delete user codes 1-8
- Create/delete a Time Delay Override Code (PIN 9)
7 7 * Detect active PIN positions.
Lock Identification:
Enter 4 3 * and listen carefully for the lock identification beeps.
Beep Set Lock Identification: Number of Beeps
1st set (high/short):
Lock Model
Deadlocking
motor
(6124)
4 beeps
Push/pull motor
(6125)
5 beeps
---
2nd set (low/long):
Access Type
Single User
1 beep
Multiple User
2 beeps
Dual Control
3 beeps
Reference for Beep Patterns
Action/Condition What You Hear
Wrong code entered 1 long continuous beep
Code entered during error penalty time 2 long continuous beeps
User code entered to start time delay 3 short high-pitch beeps
Time delay countdown 1 short high-pitch beep every 10 seconds
Time delay expiration signal 10 short high-pitch beeps
Opening Window signal 2 short high-pitch beeps every 6 seconds
Low Battery Warning 5 sets of 2 short high-pitch beeps
Battery too low to perform functions 20 short high-pitch beep (code lockout)
Bolt extension indicator 1 low/high beep sequence
Keypad tamper signal (optional) 2 sequences of SOS (3 short-high, 3 short-low, 3 short-high)
End of Audit Trail download 3 high pitch beeps
Enable lock (Management/ Employee mode) 4 high pitch beeps
Disable lock (Management/ Employee mode) 2 low pitch beeps